Un componente fundamental e indispensable de todo sistema de refrigeración es el control de flujo, o dispositivo reductor de presión. Sus fines principales son:
1. Mantener la presión y punto de ebullición adecuados en el evaporador para manejar la carga térmica deseada.
2. Permitir el flujo del refrigerante hacia el evaporador a la velocidad necesaria para eliminar el calor de la carga.
2. Permitir el flujo del refrigerante hacia el evaporador a la velocidad necesaria para eliminar el calor de la carga.
El dispositivo reductor de presión es uno de los puntos divisores del sistema.
El medio principal de controlar el flujo de refrigerante en los primeros años de la refrigeración, era una válvula manual básica.
El medio principal de controlar el flujo de refrigerante en los primeros años de la refrigeración, era una válvula manual básica.
Al conocer su trabajo y su equipo, los primeros operadores en las fábricas de hielo y operaciones semejantes con cargar constantes, sabían hasta cuánto abrir la válvula manual de acuerdo al trabajo que se había de hacer. Sin embargo, en las aplicaciones modernas que tienen cargas variables con frecuencia, esto no es práctico, porque el ajuste de la válvula manual se tendría que cambiar de acuerdo con la variación de la carga.
A fundamental and indispensable component of any refrigeration system is to controlflow or pressure relief device. Its main purposes are:
1. Maintain the pressure and boiling point appropriate in the evaporator to handle the heat load required.
2. Permit the flow of refrigerant to the evaporator at a rate as to remove heat from the load.
The pressure reducing device is one of the points dividing the system.
The principal means for controlling refrigerant flow in the first years of refrigeration, a manual valve was basic.
Having seen his work and his team, the first operators to ice plants and similar operations with constant load, knew how to open the manual valve according to the workthat had to do. However, in modern applications often have varying loads, this is not practical, because the adjustment of the manual valve have to be changed according to the load variation.
1. Maintain the pressure and boiling point appropriate in the evaporator to handle the heat load required.
2. Permit the flow of refrigerant to the evaporator at a rate as to remove heat from the load.
The pressure reducing device is one of the points dividing the system.
The principal means for controlling refrigerant flow in the first years of refrigeration, a manual valve was basic.
Having seen his work and his team, the first operators to ice plants and similar operations with constant load, knew how to open the manual valve according to the workthat had to do. However, in modern applications often have varying loads, this is not practical, because the adjustment of the manual valve have to be changed according to the load variation.
oye pero cuantos tipos hay y donde se utilizan.
ResponderEliminaren los refrigeradores e utilisan y antes del tubo capilar
Eliminar1. Válvula automática de expansión
Eliminar2. Válvula termostática de expansión
3. Tubo capilar
4. Flotador de lado de baja
5. Flotador de lado de alta.